{"product_id":"aerotermo-ad-acqua-hc-con-diffusore-a-360","title":"Reventon HC water heater with 360° diffuser","description":"\u003cp\u003eReventon HC with a 360° diffuser is a water-fed air heater for professional use, available from Krollit, official Reventon distributor since 2007.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProduction halls\u003c\/li\u003e\n\u003cli\u003eWarehouses\u003c\/li\u003e\n\u003cli\u003eCommercial pavilions\u003c\/li\u003e\n\u003cli\u003eWorkshops\u003c\/li\u003e\n\u003cli\u003ePower range: 1.55 – 91.5 kW\u003c\/li\u003e\n\u003cli\u003eWeight: 13 – 24 kg\u003c\/li\u003e\n\u003cli\u003eCasing: EPP\u003c\/li\u003e\n\u003cli\u003eThe device is equipped with a diffuser that creates an air vortex, improving the mixing of room air with the supplied air.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWho uses the HC with 360° diffuser and for what\u003c\/h3\u003e\n\u003cp\u003eIndustrial sheds, logistics warehouses, and workshops use the HC with a 360° diffuser for water-based heating of large volume environments, with efficiency at heights up to 8-10 meters.\u003c\/p\u003e\n\u003ch3\u003eIts place in the Reventon range\u003c\/h3\u003e\n\u003cp\u003eThe Reventon HC with a 360° diffuser is part of the Reventon air heater range, distributed in Italy by Krollit since 2007. The Reventon range includes models of various categories and performances: to choose the right machine for your use case, you can consult the Reventon catalog on Krollit or contact customer support for selection assistance.\u003c\/p\u003e\n\u003ch3\u003eKrollit logistics and support\u003c\/h3\u003e\n\u003cp\u003eMachine shipping in 5-9 working days (7 days to the South of Italy). For spare parts and accessories, shipping in 3-5 working days from Krollit warehouse. Customer support in Italian available for technical documentation, product sheets, and spare parts order management. Krollit has been an official distributor since 2007.\u003c\/p\u003e\n\u003ch3\u003eWho is the HC with 360° diffuser for\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProfile\u003c\/th\u003e\n\u003cth\u003eCompatibility\u003c\/th\u003e\n\u003cth\u003eReason\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial sheds and workshops\u003c\/td\u003e\n\u003ctd\u003eSuitable\u003c\/td\u003e\n\u003ctd\u003eWater heating for large volume environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogistics warehouses and storage centers\u003c\/td\u003e\n\u003ctd\u003eSuitable\u003c\/td\u003e\n\u003ctd\u003eEfficient system for environments with heights up to 8-10 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmall residential environments\u003c\/td\u003e\n\u003ctd\u003eNot indicated\u003c\/td\u003e\n\u003ctd\u003eMachine sized for industrial spaces: standard radiators are needed for home use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eNot indicated for:\u003c\/strong\u003e small residential environments (machine sized for industrial spaces: standard radiators are needed for home use).\u003c\/p\u003e\n\u003ch3\u003eOther specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWHHC15-3S-2402\u003c\/td\u003e\n\u003ctd\u003e17.2 \/ 13.4 \/ 12.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWHHC20-3S-1759\u003c\/td\u003e\n\u003ctd\u003e21.4 \/ 17.3 \/ 13.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWHHC30-3S-1760\u003c\/td\u003e\n\u003ctd\u003e26.4 \/ 20.3 \/ 15.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWHHC35-3S-1761\u003c\/td\u003e\n\u003ctd\u003e30.3 \/ 22.9 \/ 17.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWHHC45-3S-1762\u003c\/td\u003e\n\u003ctd\u003e42.0 \/ 28.9 \/ 21.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWHHC50-3S-2006\u003c\/td\u003e\n\u003ctd\u003e49.8 \/ 45.2 \/ 34.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWHHC70-3S-1764\u003c\/td\u003e\n\u003ctd\u003e60.6 \/ 40.1 \/ 32.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWHHC80-3S-1956\u003c\/td\u003e\n\u003ctd\u003e69.2 \/ 61.5 \/ 46.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat thermal power does the HC with 360° diffuser deliver?\u003c\/summary\u003e\n\u003cp\u003eSee \"Thermal power\" in the table: typically 10-100 kW at nominal water temperature.\u003c\/p\u003e\n\u003cp\u003eThe declared power refers to water at 80°C supply and 60°C return with ambient at 15°C. For different conditions, the output varies proportionally.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat volume of environment is it sized for?\u003c\/summary\u003e\n\u003cp\u003eSee the recommended volume data: typically 200-2,000 m³ depending on the model.\u003c\/p\u003e\n\u003cp\u003eSizing depends on the building's insulation, heat losses, and minimum outdoor temperature. Consider a 20% margin on the nominal calculation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat hydraulic system does it require?\u003c\/summary\u003e\n\u003cp\u003eConnection to hot water circuit with shut-off and balancing valves.\u003c\/p\u003e\n\u003cp\u003eInstallation with ball valves, a Y-filter on the inlet, and a bleed valve on the supply is recommended. Max operating pressure indicated in the technical table.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs the fan speed adjustable?\u003c\/summary\u003e\n\u003cp\u003eModern models offer EC motors with continuous regulation, traditional ones have 2-3 fixed speeds.\u003c\/p\u003e\n\u003cp\u003eEC motors consume up to 60% less and allow fine modulation. They are recommended for residential or commercial installations.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat electrical connection does it require?\u003c\/summary\u003e\n\u003cp\u003eSee \"Voltage\" and \"Power consumption\" of the motor: typically 230 V single-phase for small models, 400 V for large models.\u003c\/p\u003e\n\u003cp\u003eModels with EC motors require shielded cables and connection to the regulation system (0-10 V or digital signal).\u003c\/p\u003e\n\u003c\/details\u003e","brand":"Reventon","offers":[{"title":"WHHC15D360-3S-2422","offer_id":50697872834888,"sku":"WHHC15D360-3S-2422","price":475.21,"currency_code":"EUR","in_stock":true},{"title":"WHHC20D360-3S-1767","offer_id":50697872867656,"sku":"WHHC20D360-3S-1767","price":492.04,"currency_code":"EUR","in_stock":true},{"title":"WHHC30D360-3S-1768","offer_id":50697872900424,"sku":"WHHC30D360-3S-1768","price":528.01,"currency_code":"EUR","in_stock":true},{"title":"WHHC35D360-3S-1769","offer_id":50697872933192,"sku":"WHHC35D360-3S-1769","price":588.02,"currency_code":"EUR","in_stock":true},{"title":"WHHC45D360-3S-1770","offer_id":50697872965960,"sku":"WHHC45D360-3S-1770","price":624.02,"currency_code":"EUR","in_stock":true},{"title":"WHHC50D360-3S-1771","offer_id":50697872998728,"sku":"WHHC50D360-3S-1771","price":672.02,"currency_code":"EUR","in_stock":true},{"title":"WHHC70D360-3S-1772","offer_id":50697873031496,"sku":"WHHC70D360-3S-1772","price":744.02,"currency_code":"EUR","in_stock":true},{"title":"WHHC80D360-3S-1960","offer_id":50697873064264,"sku":"WHHC80D360-3S-1960","price":768.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/2139\/0920\/files\/Aerotermo_ad_acqua_HC_con_diffusore_a_360.webp?v=1751191156","url":"https:\/\/www.krollit.com\/products\/heater-fan-ad-acqua-hc-with-diffusore-a-360","provider":"Krollit","version":"1.0","type":"link"}