{"product_id":"set-aerotermo-ad-acqua-hc","title":"Reventon Mini HC Water Heater","description":"\u003cp\u003eReventon Mini HC is a water-fed air heater for professional use, available from Krollit, an official Reventon distributor since 2007.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSilent and reliable operation\u003c\/li\u003e\n\u003cli\u003e3-speed fan\u003c\/li\u003e\n\u003cli\u003eModern design\u003c\/li\u003e\n\u003cli\u003ePower: from 1.55 to 91.5 kW\u003c\/li\u003e\n\u003cli\u003eWeight: from 13 to 24 kg\u003c\/li\u003e\n\u003cli\u003eCasing made of 100% recyclable EPP material\u003c\/li\u003e\n\u003cli\u003eHeat exchanger with 1, 2 or 3 rows depending on the model\u003c\/li\u003e\n\u003cli\u003eFan with IP54 protection compliant with the European ErP 2015 directive\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWho uses the Mini HC and for what\u003c\/h3\u003e\n\u003cp\u003eIndustrial sheds, logistics warehouses, and workshops use the Mini HC for water heating of large volume spaces, with efficiency at heights up to 8-10 meters.\u003c\/p\u003e\n\u003ch3\u003eIts place in the Reventon range\u003c\/h3\u003e\n\u003cp\u003eReventon Mini HC is part of the Reventon air heater range, distributed in Italy by Krollit since 2007. The Reventon range includes models of various categories and performances: to choose the right machine for your use case, you can consult the Reventon catalog on Krollit or contact customer support for selection assistance.\u003c\/p\u003e\n\u003ch3\u003eKrollit logistics and support\u003c\/h3\u003e\n\u003cp\u003eMachine shipping in 5-9 working days (7 days for Southern Italy). For spare parts and accessories, shipping in 3-5 working days from Krollit warehouse. Italian-speaking customer support available for technical documentation, product sheets, and spare parts order management. Krollit has been an official distributor since 2007.\u003c\/p\u003e\n\u003ch3\u003eWho the Mini HC is for\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProfile\u003c\/th\u003e\n\u003cth\u003eCompatibility\u003c\/th\u003e\n\u003cth\u003eReason\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial sheds and workshops\u003c\/td\u003e\n\u003ctd\u003eSuitable\u003c\/td\u003e\n\u003ctd\u003eWater heating for large volume spaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogistics warehouses and storage centers\u003c\/td\u003e\n\u003ctd\u003eSuitable\u003c\/td\u003e\n\u003ctd\u003eEfficient system for spaces with heights up to 8-10 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmall residential environments\u003c\/td\u003e\n\u003ctd\u003eNot suitable\u003c\/td\u003e\n\u003ctd\u003eMachine sized for industrial spaces: standard radiators are needed for homes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eNot suitable for:\u003c\/strong\u003e small residential environments (machine sized for industrial spaces: standard radiators are needed for homes).\u003c\/p\u003e\n\u003ch3\u003eOther specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHC15-3S\u003c\/td\u003e\n\u003ctd\u003e17.2 \/ 13.4 \/ 12.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHC20-3S\u003c\/td\u003e\n\u003ctd\u003e21.4 \/ 17.3 \/ 13.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHC30-3S\u003c\/td\u003e\n\u003ctd\u003e26.4 \/ 20.3 \/ 15.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHC35-3S\u003c\/td\u003e\n\u003ctd\u003e30.3 \/ 22.9 \/ 17.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHC45-3S\u003c\/td\u003e\n\u003ctd\u003e42.0 \/ 28.9 \/ 21.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHC50-3S\u003c\/td\u003e\n\u003ctd\u003e49.8 \/ 45.2 \/ 34.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHC70-3S\u003c\/td\u003e\n\u003ctd\u003e60.6 \/ 40.1 \/ 32.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHC80-3S\u003c\/td\u003e\n\u003ctd\u003e69.2 \/ 61.5 \/ 46.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat thermal power does the Mini HC deliver?\u003c\/summary\u003e\n\u003cp\u003eSee \"Thermal Power\" in the table: typically 10-100 kW at nominal water temperature.\u003c\/p\u003e\n\u003cp\u003eThe declared power refers to water at 80°C supply and 60°C return with an ambient temperature of 15°C. For different conditions, the output varies proportionally.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat room volume is it sized for?\u003c\/summary\u003e\n\u003cp\u003eSee the recommended volume data: typically 200-2,000 m³ depending on the model.\u003c\/p\u003e\n\u003cp\u003eSizing depends on building insulation, heat losses, and minimum external temperature. Consider a 20% margin on the nominal calculation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat plumbing system does it require?\u003c\/summary\u003e\n\u003cp\u003eConnection to a hot water circuit with shut-off and balancing valves.\u003c\/p\u003e\n\u003cp\u003eInstallation with ball valves, a Y-strainer at the inlet, and a bleed valve on the supply is recommended. Max operating pressure indicated in the technical table.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs the fan speed adjustable?\u003c\/summary\u003e\n\u003cp\u003eModern models offer an EC motor with continuous regulation, traditional ones have 2-3 fixed speeds.\u003c\/p\u003e\n\u003cp\u003eEC motors consume up to 60% less and allow fine modulation. They are recommended for residential or commercial installations.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat electrical connection does it require?\u003c\/summary\u003e\n\u003cp\u003eSee \"Voltage\" and \"Absorbed Power\" of the motor: typically 230 V single-phase for small models, 400 V for large models.\u003c\/p\u003e\n\u003cp\u003eModels with EC motors require shielded cables and connection to the control system (0-10 V or digital signal).\u003c\/p\u003e\n\u003c\/details\u003e","brand":"Reventon","offers":[{"title":"Set HC15-3S","offer_id":50697848029512,"sku":"WHHC15-3S-RH-2425","price":374.41,"currency_code":"EUR","in_stock":true},{"title":"Set HC20-3S","offer_id":50697848062280,"sku":"WHHC20-3S-RH-1947","price":391.21,"currency_code":"EUR","in_stock":true},{"title":"Set HC30-3S","offer_id":50697848095048,"sku":"WHHC30-3S-RH-1948","price":427.21,"currency_code":"EUR","in_stock":true},{"title":"Set HC35-3S","offer_id":50697848127816,"sku":"WHHC35-3S-RH-1949","price":487.21,"currency_code":"EUR","in_stock":true},{"title":"Set HC45-3S","offer_id":50697848160584,"sku":"WHHC45-3S-RH-1950","price":523.21,"currency_code":"EUR","in_stock":true},{"title":"Set HC50-3S","offer_id":50697848193352,"sku":"WHHC50-3S-RH-1951","price":576.02,"currency_code":"EUR","in_stock":true},{"title":"HC70-3S Set","offer_id":50697848226120,"sku":"WHHC70-3S-RH-1952","price":648.02,"currency_code":"EUR","in_stock":true},{"title":"Set HC80-3S","offer_id":50697848258888,"sku":"WHHC80-3S-RH-1957","price":672.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0891\/2139\/0920\/files\/Set_Aerotermo_ad_acqua_Mini_HC.webp?v=1751193069","url":"https:\/\/www.krollit.com\/products\/set-heater-fan-ad-acqua-hc","provider":"Krollit","version":"1.0","type":"link"}